Skip to main content

CSTSE | China Steam Turbine Service Expert

50MW-200MW

HomeProductsSTI-N150 Condensing Steam Turbine

STI-N150 Condensing Steam Turbine

Introduction Our steam turbines, rated 135–160MW, are engineered for conventional steam power plants. With over 100 units of this type already in service across China, we deliver mature, field-proven technology — backed by decades of manufacturing and commissioning experience. Specification of Condensing Turbine High-efficiency condensing steam turbine units for power generation. Super-high pressure, single reheat, […]

Model
STI-N150
Capacity
135-160MW

Introduction

Introduction

Our steam turbines, rated 135–160MW, are engineered for conventional steam power plants. With over 100 units of this type already in service across China, we deliver mature, field-proven technology — backed by decades of manufacturing and commissioning experience.

Specification of Condensing Turbine

High-efficiency condensing steam turbine units for power generation. Super-high pressure, single reheat, tandem two-casing two-flow design, 3000 r/min (50 Hz).

Item 150MW Condensing Turbine 150MW Condensing Turbine 135MW Condensing Turbine 135MW Condensing Turbine 135MW Condensing Turbine
Product Model N150-13.24/535/535 N150-13.24/535/535 N135-13.24/535/535 N135-13.24/535/535 N135-13.24/535/535
Product Type Super-high pressure, single reheat, tandem, two casing, two flow Super-high pressure, single reheat, tandem, two casing, two flow Super-high pressure, single reheat, tandem, two casing, two flow Super-high pressure, single reheat, tandem, two casing, two flow Super-high pressure, single reheat, tandem, two casing, two flow
Rated Output (MW) 150 150 135 135 135
Max. Output (MW) 163 163.675 147 150 141
Speed (r/min) 3000 3000 3000 3000 3000
Steam Pressure before MSV (MPa) 13.24 13.24 13.24 13.24 13.24
Steam Temperature before MSV (℃) 535 535 535 535 535
Reheat Temperature (℃) 535 535 535 535 535
Rated Steam Flow (t/h) 434.64 432.49 398.82 393.43 399
Max. Steam Flow (t/h) 480 480 440 450 440
Exhaust Pressure (MPa) 0.0060 0.0049 0.0049 0.0049 0.0062
Stage Number I + 8 + 9 + 6×2 = 30 I + 8 + 9 + 6×2 = 30 I + 8 + 10 + 6×2 = 31 I + 8 + 10 + 6×2 = 31 I + 8 + 10 + 6×2 = 31
Stage of Heater 2 (HP) + 1 (deaerator) + 4 (LP) 2 (HP) + 1 (deaerator) + 4 (LP) 2 (HP) + 1 (deaerator) + 4 (LP) 2 (HP) + 1 (deaerator) + 4 (LP) 2 (HP) + 1 (deaerator) + 4 (LP)
Cooling Water Temperature (℃) 25 20 20 / 33 20 / 33 25 / 33
Feedwater Temperature (℃) 241.6 241.6 244.9 241.3 243.7
Length of L−0 Bucket (mm) 710 710 668 668 668
Gland Steam System
Overall Dimension above Operation Floor (L×W×H, m) 13.5 × 7.5 × 5 13.5 × 7.5 × 5 13.5 × 7.5 × 5
Total Weight of Turbine Proper (t) 320 350 350
Max. Lifting Weight during Installation (t)
Surface of Condenser (m²) 8500 8700 8000
Remarks Heat rate for Yuling project: 8158. kJ/kW·h, rated steam flow 396.86397 t/h 1# unit: 139-5; 2# unit: 139-6 Combined HP/IP casing
Note: All parameters are as supplied by the manufacturer and may be adapted to site conditions.
ModelSTI-N150
Capacity / Output135-160MW
DocumentationAvailable on request or through the anonymous brochure download.